Instrument Transformer

JDZ9-27.5Q JDZ9-35Q JDZX9-35G JDZ9-35G FULLY-ENCLOSED INDOOR SINGLE-PHASE VOLTAGE TRANSFORMER

The instrument transformer can be divided into two types, which are voltage transformer and current transformer. The main functions are as follows: accurately transfer voltage and current information of the primary system to the related equipment at the secondary side; convert the high voltage and high current of the primary system to low voltage (standard value) and low current (standard value) at the secondary side, conduct standardization and miniaturization of the measuring instrument, relay and other devices, and lower requirements for isolation of secondary equipment; well isolate the secondary side equipment and secondary system from the high-voltage equipment of the primary system electrically, so as to guarantee secondary equipment and personnel safety.

 

The working principle is the same with the transformer, and the basic structure is also iron core and primary and secondary windings. The features of the instrument transformer are: small in capacity and very constant , and it is close to no-load state during normal operation. Impedance of the voltage transformer is very small. In case of any short circuit at the secondary side, the current will be sharply increased, leading to coil burnout. For this reason, the primary side of the voltage transformer is connected with fuse, and the secondary side is reliably grounded, so as to avoid personal and equipment accident due to high potential against ground at the secondary side when insulation at the primary and secondary sides is damaged. The voltage transformer for measurement generally has a single-phase double-coil structure, the primary voltage is the measured voltage (similar to the line voltage of the power system), which can be used as single phase, and can also be used as three-phase when two sets form a V-V shape. The voltage transformer that is used in laboratory has multiple taps at the primary side, so as to adapt to demands for different voltages. The voltage transformer for protective grounding is also provided with a tertiary coil, which is called as the tertiary coil voltage transformer. Three-phase tertiary coil is connected to form open triangle, and two leading-out terminals of the open triangle are connected with the voltage coil of the grounding protection relay. During normal operation, three-phase voltage of the power system is symmetrical, and the sum of three-phase induced electromotive force on tertiary coil is zero. In case of single-phase grounding, there is a displacement of the neutral point, and there will be zero-sequence voltage between terminals of open triangle, so as to protect the power system. In case of zero-sequence voltage of the coil, there will be zero sequence magnetic flux in the corresponding iron core. Therefore the side yoke type iron core or three single-phase voltage transformer is adopted for the three-phase voltage transformer (10kV and below). For such instrument transformer, the requirements for the accuracy of the tertiary coil are not high. However, it requires a certain overexcitation characteristic (i.e., when the primary voltage is increased, magnetic flux density in the iron core will also be increased by the corresponding multiple, and damage will not be caused).

 

Equivalent circuit of the electromagnetic inductive voltage transformer is the same with that of the transformer.

  • The instrument transformer is an equipment that changes voltage or current in proportion. The function of the instrument transformer is to change high voltage or high current to standard low voltage (100v) or standard low current (5A or 10A, refer to the rated value) in proportion, so as to achieve standardization and miniaturization of the measuring instrument, protection equipment, and control equipment.


    The instrument transformer can also be used to separate the high voltage system, so as to guarantee personnel and equipment safety. It is the equipment that changes voltage or current in proportion. The power system used instrument transformer is a special transformer which transfers the information of high voltage and high current of the power grid to measure instrument, relay protection and automatic devices at the secondary side with low voltage and low current. It is the contact element between the primary and the secondary systems, the primary winding is accessed to the power grid, and the secondary winding is connected with the measuring instrument and protection devices, etc. The instrument transformer coordinates with the measuring instrument and metering devices, which can measure voltage, current and electrical energy of primary system; It coordinates with relay protection and automatic devices, which can achieve electrical protection and automatic control of various faults of the power grid. Performance of the instrument transformer directly influences the accuracy of measurement and measuring of the power system, and reliability of action of the relay protection devices.


Contact information

Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Sales Team

  • NameKai Wang
  • AddressHuaxin Industrial Park, Yangquan, Shanxi, China 045000
  • PhoneChina:15234310529,Canada:+1 3067132408
  • E-mailkwang@hxindustrial.com
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Service Team

  • NameKai Wang
  • AddressHuaxin Industrial Park, Yangquan, Shanxi, China 045000
  • PhoneChina:15234310529,Canada:+1 3067132408
  • E-mailkwang@hxindustrial.com
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Cooperation Team

  • NameKai Wang
  • AddressHuaxin Industrial Park, Yangquan, Shanxi, China 045000
  • PhoneChina:15234310529, Canada:+1 3067132408
  • E-mailkwang@hxindustrial.com
Close

©1996-2023 晋ICP备07500050号 Huaxin Copyright 

©1996-2023 晋ICP备07500050号 Huaxin Copyright