Hello, welcome to Huaxin
Electric Locomotive Series

Explosion-proof Special Battery Power Supply Device

The power supply device can be taken as a DC power supply for the Mining Explosion-proof Special Battery Electrical Locomotive.

  •     Technical Parameters

        2.1 Basic Technical Parameters (see Table 1 and Table 2)

    Table I Basic Technical Parameters of the Power Supply Device

    Model of Power 

    Supply Device

    Rated 

    Voltage (VDC)

    Rated 

    Capacity (Ah)

    Maximum Overall Dimensions (mm)

    Weight (kg)

    Length

    Broadband

    High

    Without 

    Solution

    With 

    Solution

    DXT-90/330

    90

    330

    1929

    1000

    567

    1270

    1607.5

    DXT-48/330

    48

    330

    1000

    915

    567

    760

    940

    DXT-140/440

    140

    440

    2800

    1050

    500

    1900

    2565

    DXT-192/560

    192

    560

    2670

    1050

    620

    3376

    4096

         

    Table II Basic Technical Parameters of the Monomer Battery

         

    Battery Model

    Rated Voltage (VDC)

    Rated Capacity (Ah)

                        Maximum Overall Dmensions (mm)

    Weight (kg)

    Length

    Broadband

    High

    Without Solution

    With Solution

    D330KT

    2

    330

    137

    181

    460

    15

    22.5

    D440KT

    2

    440

    208

    160

    374

    19.5

    29

    D560KT

    2

    560

    145

    163

    575

    25

    33.5

         

         

         

        2.2 Discharge Performance (see Table 3)

    Table 3 Discharge Performance

    Battery

                        Model

    5 Hour Rate

    3 Hour Rate

    1 Hour Rate

    Final voltage of discharging 1.70V

    Current (A)

    Capacity (Ah)

    Current (A)

    Capacity (Ah)

    Current (A)

    Capacity (Ah)

    D330KT

    66

    330

    91

    237

    330

    165

    D440KT

    88

    440

    122

    366

    264

    264

    D560KT

    112

    560

    155

    465

    336

    336

         

        2.3 Charging Performance (see Table 4)

    Table 4 Charging Performance

    Battery Model

    Initial Charging

    Common Charging

    Stage I

    Stage II

    Current (A)

    Time (h)

    Current (A)

    Time (h)

    Current (A)

    Time (h)

    D330KT

    45-50

    25-30

    23-26

    45-50

    50-60

    12-14

    D440KT

    45-50

    25-30

    23-26

    45-50

    50-60

    12-14

    D560KT

    55-60

    25-30

    30-35

    45-50

    60-70

    12-14

  • The Explosion-proof Special Power Supply Device consists of a special lead-acid battery, a battery box, connecting wires and a mining explosion-proof male pin connector, which can be used with the Explosion-proof Special Battery Electrical Locomotive in coal mines full with methane or coal dust explosion hazard.

  • 1. The product is an Exsl Mining Explosion-proof Special Model. The structure performance conforms to the requirements in MT/T334-2008, GB10978-89 and GB3836.1-2000, and is appraised by related explosion-proof inspection station authorized in China.

    2. The product mainly consists of a glass fiber tubular anode plate, a paste negative plate, a micro rubber or plastic partition board, an ethylene-propylene copolymer plastic battery jar, a battery cover and sulfuric acid electrolyte. Body hot-melt sealing is adopted for the battery jar and battery cover.

    3. When the unit cells are combined into a battery pack, a special wire is used for soldering connection to reduce the contact resistance and prevent the spark from being generated, ensuring the safety of the use and the good wire connection of the battery pack under special circumstances.

    4. In order to avoid short circuit of the battery pack, the exposed position of the electrical conductor shall be covered with insulated plastic sheath.

    5. Sealant is applied on the casting interface of the connecting wire, so as to prevent corrosion of sulfuric acid, and guarantee safe use.

    6. The acid-resistant special working plug is adopted for the battery, and is subject to hydrophobic treatment, so as to guarantee good air permeability of the battery, and reduce water consumption of electrolyte.

  • 1. It is applicable for roadway with gas and coal dust explosion hazard.

    2. The elevation shall not exceed 1,200m.

    3. The maximum ambient temperature shall be 40℃/140℉, and the minimum shall be -20℃/-4℉.

    4. The monthly average maximum relative humidity of the wettest month shall be less than 95% (the monthly average minimum temperature of the same month shall not be higher than 25℃/77℉).

    5. No gas or conductive dust in the air enabling to cause corrosion to metal or damage insulation.

    6. The maximum acceleration of impacts in the longitudinal direction of the electrical locomotive shall be no more than 30m/s2.

    7. The narrow-gauge track roadbed and the turnout laying quality shall conform to provisions in GBJ213 Article 328: Safety Rules for Coal Mine.

Contact information

Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Sales Team

  • NameKai Wang
  • Address813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529,Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Service Team

  • NameKai Wang
  • Address 813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529,Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Cooperation Team

  • NameKai Wang
  • Address813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529, Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close

©1996-2017 晋ICP备07500050号 Huaxin Copyright 

©2016-2017 晋ICP备07500050号 Huaxin Copyright